Coriolis (CMD)

Flow sensor FCS200

Flow Measurement Flow Sensor SUTRANS FCS200 Coriolis
SITRANS FCS200 (DN10, DN 15 and DN 25) is a Coriolis sensor specialized for accurate mass flow measurement of gases. The sensor offers superior performance in terms of flow accuracy and turn down ratio. The ultra compact sensor design makes installation, replacement and commissioning very straight forward and easy.
SITRANS FCS200 is designed for measurement of gases and is suitable for use in the oil and gas industry:
  • filling of gas bottles
  • CNG dispensers
  • metering of general gas applications

Download:
Flow sensor FCS200
Inquiry Sheet
  • DN10, DN15, DN25
  • flow from 0 to 30 000 kg/h
  • pipe material: Hastelloy C22
  • accuracy: ± 0.5 % of rate
  • process temperature: -40 to +125 °C (-40 to 257 °F)
  • pressure: Up to 350 bar
  • approvals: II 1/2 G Ex ia IIC T5-T4



Flow sensor MASS 2100 (single tube design)

Flow Measurement Flow Sensor MASS2100 DI 3-40 Coriolis
MASS 2100 DI 3 to DI 40 is suitable for accurate mass flow measurement of a variety of liquids and gases.
The sensor offers superior performance in terms of flow accuracy, turn-down ratio and density accuracy. The ease of installation through a "plug & play" mechanical and electrical interface ensures optimum performance and operation. The sensor delivers true multi-parameter measurements i.e.: Mass flow, volume flow, density, temperature and fraction.

Download:
Sensor MASS 2100
Inquiry Sheet
  • DI 3, DI 6, DI 15, DI 25, DI 40 and DN 4
  • flow from 0.1 to 52 000 kg/h (114 640 lb/h)
  • pipe material: W 1.4435 (316L); W 2.4602 Hastelloy C22
  • accuracy, typically:
    • flow: ≤ 0.1% of flow rate
    • density: ≤ 0.0005 g/cm3
  • liquid temp./pressure: -50 to +180°C (-58 to +356 °F) / Up to 410 bar (5946 psi)
  • approved according to ATEX EEx ia IIC T3 to T6



Flow sensor MASS 2100 DI 1.5

Flow Measurement Flow Sensor MASS2100 DI 1,5 Coriolis
MASS 2100 DI 1.5 is suitable for low flow measurement applications of a variety of liquids and gases. The sensor offers superior performance in terms of flow accuracy, turn-down ratio and density accuracy. The ease of installation through a "plug & play" mechanical and electrical interface ensures optimum performance and operation. the sensor delivers true multi-parameter measurements i.e.: Mass flow, volume flow, density, temperature and fraction.

The single continuous tube design, with no internal welds, reductions or flow splitters offers optimal hygiene, safety and CIP cleanability for food and beverage and pharmaceutical applications.

Download:
Flow sensor MASS 2100 DI 1.5
Inquiry Sheet
  • temperature:
    • standard version up to 125°C (257 °F)
    • high-temperature version up to 180 °C (356 °F)
  • density accuracy higher than 0,001 g/cm3
  • large dynamic turn-down ratio better than 500:1, from 65 kg/h to a few g/h
  • repeatability better than 0.0002 g/cm3
  • material: stainless steel AISI 316L mat. no. 1.4404 with a grade of encapsulation of IP65/NEMA 4
  • 4-wire Pt1000 temperature measurement ensures optimum accuracy on mass flow, density and fraction flow



Flow sensor FC300

Flow Measurement Flow Sensor SUTRANS FC300 Coriolis
SITRANS FC300 is a compact Coriolis mass sensor suitable for flow measurement of a variety of liquids and gases. The sensor offers superior performance in terms of flow accuracy, turn-down ratio and density accuracy. The ease of installation through a „plug & play“ interface ensures optimum performance and operation. A new designed encapsulation in stainless steel with a surprisingly low weight of only 3.5 kg (7.7 lb), ensures a rigid and robust sensor performance for a wide range of applications.

Download:
Flow sensor FC300
Inquiry Sheet
  • DI 3, DI 6, DI 15, DI 25, DI 40 and DN 4
  • flow from 0.1 to 52 000 kg/h (114 640 lb/h)
  • pipe material: W 1.4435 (316L); W 2.4602 Hastelloy C22
  • accuracy, typically:
    • flow: ≤ 0.1% of flow rate
    • density: ≤ 0.0005 g/cm3
  • liquid temp./pressure: -50 to +180°C (-58 to +356 °F) / Up to 410 bar (5946 psi)
  • approved according to ATEX EEx ia IIC T3 to T6



Flow sensor MC2 (dual tube design)


Flow Measurement Flow Sensor MC2 Coriolis
Flow Sensor MC2 Coriolis Hygienic
The MC2 sensor is suitable for accurate mass flow measurement of a variety of liquids and gases. The sensor offers superior performance in terms of flow accuracy, turn-down ratio and density accuracy and delivers true multi-parameter measurements i.e.: mass flow, volume flow, density, temperature and fraction flow. The very compact sensor construction makes installation and commissioning of even the largest sizes very straight forward and easy.
The MC2 sensor is also available in a hygienic version which is EHEDG-approved. This is of particular interest for the food and beverage and pharmaceutical markets were the EHEDG approval is often requested for optimum hygienic and process safety.

Download:
Flow sensor MC2 und MC2 Hygienic
Inquiry Sheet
  • Standard MC2:
    • DN 50, DN 65, DN 80, DN 100 and DN 150
    • flow from 0 to 510 000 kg/h (112 400 lb/h)
    • tube material: W 1.4571 (316Ti) and Hastelloy C4
  • Hygienic MC2:
    • Approvals: EHEDG
    • DN 20, DN 25, DN 40, DN 50, DN 65 and DN 80
    • Flow from 0 to 113 600 kg/h (250 000 lb/h)
    • Tube material: W 1.4435 (316L)
    • Connectors: DIN 11851, DIN 32676 and DIN 11864-2A
  • Accuracy: ≤ 0.15% of rate
  • Density: ≤ 0.001 g/cm3
  • Liquid temp.: -50 to +180 °C (-58 to +356 °F)
  • Pressure: < 100 bar (1450 psi)
  • Approvals: ATEX EEx em [ib] IIC T2 to T6


Transmitter MASS 6000 Ex d

Flow Measurement Transmitter ex d compact/remote MASS 6000 Coriolis
Mass flow meters according to the coriolis measurement principle can be used for measuring of fluids and gases. The measurement is indepentant for change in process conditions and parameters like temperature, density, pressure, viscoisty, conductivity and flow pattern.
The devices can be installed easily. Coriolis flow meter are well known for high precision in a great range.
The MASS 6000 Ex d transmitter is manufactured in stainless steel (AISI 316L) and able to withstand harsh installation conditions in hazardous applications within the process and chemical industry. The conservative choice of material guarantees the user a low cost of ownership and a long trouble-free life-time. The Ex d can be compact mounted on all sensors of type MASS 2100 DI 3 to DI 40, and can be used in remote version for all types of MASS 2100.

Main applications:
  • chemical process industry
  • pharmaceutical industries
  • automotive industry
  • oil and gas industry
  • power generation and utility industry

Download:
Transmitter MASS 6000 Ex d
Inquiry Sheet
  • digital signal processing measuring 30 times a second
  • 3 current, 2 frequence and 2 relay outputs
  • adaptive batch function
  • SENSORPROM memory unit making iteasy to start up the flowmeter.
  • easy retrofitting of communication modules (AOM)
  • approved according to ATEX [EEx ia] IIC / EEx de [ia/ib] IIC T6
  • true multiparameter measurements i.e.: Mass flow, volume flow, density, temperature and fraction flow



Transmitter MASS 6000 IP67

Flow Measurement Transmitter MASS 6000 IP67 Coriolis
The MASS 6000 IP67 transmitter can be compact mounted on all sensors of type MASS 2100 DI 3 to DI 40, and can be used in remote version for all types of MASS 2100/MC2 and FC300 sensors.

Main applications:
  • food and beverage industries
  • pharmaceutical industries
  • automotive industry
  • oil and gas industry
  • power generation and utility industry
  • water and waste water industry

Download:
Transmitter MASS 6000 IP67
Inquiry Sheet


  • digital signal processing measuring 30 times a second
  • 3 current, 2 frequence and 2 relay outputs
  • adaptive batch function
  • SENSORPROM memory unit making iteasy to start up the flowmeter.
  • easy retrofitting of communication modules (AOM)
  • approved according to ATEX [EEx ia] IIC / EEx de [ia/ib] IIC T6
  • true multiparameter measurements i.e.: Mass flow, volume flow, density, temperature and fraction flow



Transmitter MASS 6000 for 19" Insert

Flow Measurement Transmitter 19
MASS 6000 is based on the latest developments within digital signal processing technology – engineered for high performance, fast flow step response, fast batching applications, high immunity against process noise, easy to install, commission and maintain.
The MASS 6000 transmitter delivers true multi parameter measurements i.e.: Mass flow, volume flow, density, temperature and fraction.

The MASS 6000 19" transmitter can be connected to all sensors of types MASS 2100/MC2/FC300 and are available in different versions depending of number of output facilities, Ex protection and grade of enclosure.

Main applications:
  • chemical and pharmaceutical industries
  • food and beverage industries
  • automotive industry
  • oil and gas industry
  • power generation and utility industry
  • water and waste water industry
Download:
Transmitter MASS 6000 for 19"
Inquiry Sheet
  • digital signal processing measuring 30 times a second
  • 3 current, 2 frequence and 2 relay outputs
  • adaptive batch function
  • SENSORPROM memory unit making iteasy to start up the flowmeter.
  • easy retrofitting of communication modules (AOM)
  • approved according to ATEX [EEx ia] IIC / EEx de [ia/ib] IIC T6



Flow sensor SIFLOW FC070

Flow Measurement Transmitter SIFLOW FC070 Coriolis
SIFLOW FC070 is based on the latest developments within the digital processing technology – engineered for high performance, fast flow step response, immunity against process generated noise, easy to install, commission and maintain.
The SIFLOW FC070 transmitter delivers true multi-parameter measurements i.e. mass flow, volume flow, density, temperature and fraction.

SIFLOW FC070 is available in two versions:
  • SIFLOW FC070 Standard
  • SIFLOW FC070 Ex
Main applications:
  • food and beverage
  • pharmaceutical
  • automotive
  • oil and gas
  • power generation and utility
  • water and waste water

Download:
Flow meter SIFLOW FC070
Inquiry Sheet
  • digital signal processing measuring 30 times a second.
  • 3 current, 2 freq. and 2 relay outputs
  • adaptive batch function
  • SENSORPROM memory unit making it easy to start up the flowmeter.
  • easy retrofitting of communication modules (AOM)
  • approved according to ATEX [EEx ia] IIC / EEx de [ia/ib] IIC T6
  • multiparameter transmitter for remote or compact mounting measuring mass flow, density, temperature and fraction e.g. °Brix and °Plato