Variable Area Flow Meter


TM Trogflux

Durchflussmessgerät Schwebekörper  Trogflux
The TM Trogflux variable area meters are used to measure the volume of transparent liquids and gases passing through closed piping. The variable area meters can also be used for flow monitoring if they are equipped with one or more switching contacts.

Standard scales are available for liquids with a density of 1 kg/l (62.43 lb/cu.ft). The scales must be recalculated for all other media depending on the physical characteristics.
Applications:
  • Potable water preparation
  • Plastering machines
  • Cooling water measuring devices
  • Measurement of gas injection
  • General installation in plastic pipes

Download:
Variable Area Meter TM Trogflux
Inquiry Sheet
  • variable area flow meter
  • measurement of transparent liquids and gases
  • optional equipment with one or more switching contacts
  • low-cost plastic design
  • simple assembly and handling
  • short delivery times for standard versions
  • polyamid (optionally polysulfone) flow tube with various float materials
  • connections: G ¼"... G 2", alternatively with adhesive bushing
  • temperature of medium: max. 140 °C (284 °F)
  • optionally available with contacts



TM Tubux

  Durchflussmessgerät Schwebekörper  Tubux
The TM Tubux variable area meters are used to measure the volume of transparent liquids and gases passing through closed piping. The variable area meters can also be used for flow monitoring if they are equipped with one or more switching contacts. Standard scales are available for liquids with a density of 1 kg/l (62.43 lb/cu.ft). The scales must be recalculated for all other media depending on the physical characteristics.
The flow tube is also optionally available with a percentage or 2-mm (0.078 inch) scale.
Applications:
  • See Trogflux plus
  • Resistance against chemical and higher temperatures
  • With protected glass flow tube
  • Accuracy class 1,6

Download:
Variable Area Meter TM Tubux
Inquiry Sheet
  • variable area flow meter
  • measurement of transparent liquids and gases
  • optional equipment with one or more switching contacts
  • robust versions with various materials
  • usable for high pressure
  • short delivery times for standard versions
  • glass flow tube with various float materials
  • connections: G ¼"... G 2", alternatively with adhesive bushing
  • temperature of medium: max. 150 °C (302 °F)
  • optionally available with contacts



TM 250

 Durchflussmessgerät Schwebekörper 250
The TM 250 variable area meters with a standard length of 250 mm (9.84 inch) and a completely metal design can be used to measure many different types of liquids and gases passing through closed piping. The robust design means that they can also be used in rough conditions.

Different types of flanges, liners and float materials satisfy the requirements of the pharmaceutical and chemical industries.
The measured value is displayed directly on the scale, and output via a switch contact or as a current output.
Applications:
  • Chemical industry
  • Water
  • Power generation and distribution

Download:
Variable Area Meter TM 250
Inquiry Sheet
  • variable area flow meter
  • measurement of transparent and turbid liquids and gases
  • applicable also for corrosive or flammable media
  • measured data accessible through switch contact or current output
  • robust all metal fitting with impact resisting housing cover
  • Usable for high pressure and temperatures
  • optional heating or cooling sheaths
  • contamination insensitive guiding of float
  • short delivery times for standard versions
  • all-metal variable area meter with various float materials
  • Connections: DN 15 to DN 100 (½" to 4")
  • temperature of medium: -20 °C to +300 °C (-4 to +572 °F)
  • optionally available with analog output or contacts



TM Unox

Durchflussmessgerät Schwebekörper  Unox

The TM Unox variable area meters are used to measure the volume of transparent liquids and gases passing through closed piping. The variable area meters can also be used for flow monitoring if they are equipped with one or more switching contacts. Standard scales are available for liquids with a density of 1 kg/l (62.43 lb/cu.ft). The scales must be recalculated for all other media depending on the physical characteristics.
The measuring accuracy corresponds to class 1.6 according to VDE/VDI 3513, page 2.
Applications:

  • Chemicals and higher temperatures
  • Optional with liner (hard rubber or PTFE) of the connections
  • Accuracy class 1,6

Download:
Variable Area Meter TM Unox
Inquiry Sheet

  • variable area flow meter
  • measurement of transparent liquids and gases
  • optional equipment with one or more switching contacts
  • robust versions with various materials
  • usable for high pressure and temperatures
  • fast installation/removal of the flow tube possible without removal of the fitting
  • increased protection of users through additional cover with single-pane safety glass
  • glass flow tube with various float materials, additional cover with safety glass
  • connections: DN 15 to DN 80 (½" to 3")



Orifice Flow Meter

TM N4

   Durchfluss Messgerät Blenden N4
The TM N4 orifice flowmeter is used to measure the flow of transparent liquids in closed piping. Any mounting location, position and flow direction can be selected for the flowmeter. The flowmeter can also be used for flow monitoring if equipped with limit contacts.
Applications:
  • Potable water preparation
  • Swimming pool equipment
  • Plastering machines
  • Cooling water measuring devices
  • Measurement of gas injection
  • General installation in plastic pipes

Download:
Orifice Flow Meter TM N4
Inquiry Sheet
  • orifice flow meter
  • measurement of transparent liquids
  • optional equipment with one or more switching contacts
  • any mounting location, position and flow direction can be selected
  • measurement of flow according to differential pressure principle with bypass orifice
  • nominal diameters: DN 40 to DN 400 (1½" to 16")
  • temperature of medium: max. 60 °C (140 °F)



F O delta p

Durchfluss Messung Messblenden Messrohren
Primary differential pressure devices are standardized, mechanical flow sensors.
Through constriction of the line diameter in the device, the flow creates a differential pressure, which is converted with the help of
a differential pressure transmitter into a proportional current signal or flow value. The assignment of differential pressure to flow is created by means of an orifice plate calculation.
Applications:
  • Power stations, measurement of steam, condensate and water
  • Petrochemical industry, measurement of water, steam and liquid and gas hydrocarbons
  • Chemical industry, measurement of various liquid and gas media

Download:
Differential Pressure Device F O DELTA P
Inquiry Sheet
  • nominal diameters DN 10 to DN 1000 (0.4" to 40")
  • temperature of medium: -200 to +500 °C (-328 to +932 °F) for vapors, gases and liquids.
  • SITRANS P transmitters
  • DS III series
  • DS III PA series
  • DS III FF series



Baffle Plate with Balance Beam

TM Gardex

  Stauplatten Durchfluss Messung Gardex
The TM Gardex flowmeter is a robust device for measuring and monitoring the flow of liquid and gaseous media in any flow direction. The measured value is indicated on a scale, and is optionally available via contact switches or a current output. Standard scales are available for liquids with a density of 1 kg/l (62.43 lb/cu.ft). The accuracy corresponds to ±3% of the full-scale value.
Applications:
  • Measurement of refrigerating and heat transfer medium
  • Heating facilities
  • Building facilities
  • For high temperature

Download:
Flow Meter TM Gardex
Inquiry Sheet
  • baffle plate with balance beam
  • measurement of transparent and turbid liquids and gases
  • measured data accessible through switch contact or current output
  • robust versions with various materials
  • simple installation resulting from rugged sandwich design
  • nominal diameters: DN 25 to DN 300 (1" to 12")
  • temperature of medium: max. 300 °C (572 °F)



Flap Flow Meter

TM Intra

Klappen Durchfluss Anzeiger Intra
The TM Intra flowmeter is used to check and display the flow of liquids in closed pipelines. The device can be optionally fitted with an inductive contact for remote transmission of switching points.
Applications:
  • Chemical industry
  • Water, waste water
  • Building installations

Download:
Flap Flow Meter TM Intra
Inquiry Sheet
  • flowmeter according to the flap principle
  • suitable for transparent and turbid liquids
  • optional fitted with an inductive contact for remote transmission of switching points
  • vertical or horizontal installation
  • simple, maintenance friendly design
  • liquid temperatures up to 250 °C (482 °F)
  • robust versions with various materials
  • nominal diameters: DN 25 to DN 150 (1" to 6")
  • temperature of medium: max. 150 °C (302 °F)



TM Prima

  Anzeiger Durchfluss Klappen
The TM Prima flowmeter is used to check and display the flow of liquids in closed pipelines. The device can be optionally fitted with an inductive contact for remote transmission of switching points.
Applications:
  • Chemical industry
  • Water, waste water
  • Building installations

Download:
Flap Flow Meter TM Prima
Inquiry Sheet
  • flowmeter according to the flap principle
  • suitable for transparent and turbid liquids
  • optional fitted with an inductive contact for remote transmission of switching points
  • vertical or horizontal installation
  • simple, maintenance friendly design
  • liquid temperatures up to 250 °C (482 °F)
  • robust versions with various materials
  • nominal diameters DN 25 to DN 150 (1" to 6")
  • temperature of medium: max. 250 °C (482 °F)